Unknown · Christmas lighting chain in the form of a star
The product poses a risk of electric shock because:- the sample failed the electric strength test for Class II luminaries,- the mechanical strength of the lighting chain is insufficient, given that it failed the test with the apparatus activated by a spring, leaving the live parts accessible,- the terminals do not pass the test for the efficiency of permanent connections,- the chain’s cable are lower than that of the type of cable specified in the standard and the nominal cross-section of the conductors is 0.06 mm², which is less than the 50 mm² required by the standard,- the cable did not pass the tensile test, - the plug does not comply with IEC standard 60083,- the length of the cable between the plug and the first light-socket is 0.70 metres, which is less than the 1.50m required by the standard,- it does not provide protection against damp conditions that may arise through normal use, - it failed the electric strength test,- it failed the ball pressure test, - it does not have any markings or safety instructions. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
- Published
- 01 February 2008
- Notifying authority
- Spain
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Import rejected by the customs authorities.. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0088/08
- Model
- Unknown
Classification
- Category
- Lighting chains
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
The lighting chain consists of coloured Christmas stars into which the lights are inserted. The packaging is a transparent cellophane bag that is sealed at the top with a piece of cardboard on which is written “60 miniature lights”.