RecallLookupBack to the product checker
Serious riskSerious risk

EU Safety Gate · Report-2009-6

Jia Da · Plasma lamp

The product poses a risk of electric shock because: - the cross-section area of the cord is too small (<0.2mm2 instead of 0.5mm2), - there is no cord anchorage in the switch or in the lap, - the cover of the printed circuit board is made of flexible insulation material and fixed with glue which can easily be removed, - the glued surface can be detached when moving the lamp, thus causing live parts to be accessible. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Published
20 February 2009
Notifying authority
Hungary
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.. Date of entry into force: Unknown

Official source alert
Safety Gate reference
0223/09
Model
Unknown
Category
Lighting equipment
Risk type
Electric shock
Country of origin
Not published

The main part of the lamp is made of porous material painted in black, imitating a skull with a snake around it. The printed circuit board generating high voltage is behind a plastic cover underneath the main part. The light source is a glass globe (diameter: 10 cm). Main parts of the lamp are indicated as follows: mains plug ( "2.5 A 250 V~" + CE ); mains supply cord ("RVVB PVC INSULATED ELECTRIC WIRE 300/500V”); switch inserted into the cable ("CE-1033 3A 250V KY"); printed circuit board without identification marking. Main components of the printed circuit board: coil ("FBT-36" + date of manufacture); capacitor ("225J 400V") semi-conductor ("C2073 15 U TRANSUN"). Technical parameters: 230V~; Class II. (No technical parameters are indicated, operation by 12 V on the packaging is false.)