EU Safety Gate · Report-2008-8
Unknown · Portable lamps – 1. with a metal grille and a 10-metre extension cable, 2. with a metal grille and a 5-metre extension cable
These products pose a risk of electric shock and fire because:- the bulb socket is not attached to the lamp by two independent points,- the characteristics of the flexible mains cable do not meet the requirements,- the conductor section, which is 0.16 mm², is less than the 0.75 mm² required,- the length of the mechanism to protect against twisting is 11 mm, when it should be at least 25 mm,- it lacks an anti-traction anchoring mechanism to relieve the conductors from pull forces,- the conductor section forming the internal wiring is 0.16 mm², which is less than the 0.50 mm² required,- it lacks markings and safety instructions. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.
- Published
- 01 March 2008
- Notifying authority
- Spain
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Withdrawal from the market ordered by the authorities.. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0250/08
- Check-digit validated barcodes
- 8435188332667 · 8435188411706
Classification
- Category
- Lighting equipment
- Risk type
- Electric shock, Fire
- Country of origin
- People's Republic of China
Product description
Lamps with a metal grille and an orange extension cable measuring 10 or 5 metres. They are packed in a transparent bag closed with cardboard on which is written “PORTABLE ELECTRIC HAND LAMP 10M” or “PORTABLE ELECTRIC HAND LAMP 5M”.