EU Safety Gate · Report-2007-18
ELECTRIS · Mini steam cleaner
This product poses a risk of electric shock because:- the dielectric strength tests to approve the verification test of the degree of protection against the harmful effects due to the penetration of water caused a breakdown between the mass and the active parts after 35 seconds of application (main isolation 1 250V) and between the active parts and the external casing of the device as of the application (class II part, reinforce isolation 3 000V). The duration of the application of the test voltage set by the norm is 1 minute;- information on the supply voltage given on the data plate (220V) does not cover the standard voltage in France (230V);- in the instructions for use, some pages give the supply voltage as 220V and another page gives it as 220-240V;- furthermore, a data plate shown in the instructions for use shows a voltage of 230V and the symbol for class II devices. This product does not comply with the Low Voltage Directive and the relevant European standards.
- Published
- 11 May 2007
- Notifying authority
- France
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Other. Category of measure(s): Voluntary withdrawal from the market and recall from consumers by the importer. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0403/07
- Model
- Model: SC 225 VA, Batch: 575127
- Check-digit validated barcodes
- 3700201600722
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
The cardboard box bears the reference: # SC 225 VA – 575 127, bar code: 3 700201 600722, serial number: DOS 149, degree of protection: IPX4