EU Safety Gate · Report-2008-15
BUDERUS · Wall-mounted condensing gas boilers
The product poses a risk of fire because the housings of the defective plugs show an abnormal percentage (up to 13%) of coal (or soot) residues, and levels of polypropylene that do not correspond to those indicated in the specifications. The condition of these materials means that, contrary to the design specifications, the housings of the defective plugs are slightly electrically conductive, to a varying extent depending on the make-up of the material used. It should be noted that this leakage of current cannot in any way cause an electric shock to anyone using the equipment because the housing in question is located in an area that is not accessible.
- Published
- 18 April 2008
- Notifying authority
- Italy
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Other. Category of measure(s): Voluntary corrective action taken by the importer.. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0439/08
- Model
- Logamax plus GB 142-24 and GB 142-30 (serial numbers between 01-7246 and 01-7290).
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Fire
- Country of origin
- The Netherlands
Product description
Housing of the power connectors for the boiler’s main switch.