Serious riskSerious risk
EU Safety Gate · Report-2007-19
Extreme Heat · Fan heater/heat convector
The heater had been constructed such that the elements are in contact with the live input terminal on the selector switch. This resulted in the elements being live even when the switch was in the off position and the fan not working. As soon as the heater was plugged in, the elements rapidly heated to red-hot. Surrounding plastics ignited and the heater caught fire.
- Published
- 18 May 2007
- Notifying authority
- United Kingdom
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Other. Category of measure(s): Voluntary recall from consumers. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0444/07
- Model
- FH-90C, bar code: 5603883502163
- Check-digit validated barcodes
- 5603883502163
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Fire
- Country of origin
- People's Republic of China
Product description
Small fan heater 2000 W, marked extreme heat, packaged in blue and white box.