EU Safety Gate · Report-2008-25
SIRIUS LIGHTS · Recessed luminaires
The product poses a risk of fire because the halogen lampholder for 220V is identical to lampholders intended for extra low voltage (≤50 V). Lampholders initially intended for extra low voltage should not be used for luminaires intended for use with tungsten halogen lamps with a voltage greater than 50 V. The product does not comply with the relevant European standard EN 60598.
- Published
- 27 June 2008
- Notifying authority
- Bulgaria
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Withdrawal from the market ordered by the authorities.. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- 0675/08
- Model
- “Mars system moons” with following numbers: 017513, 017725, 017953, 017943, 017793, 017853, 017903, 017905, 017875, 017705, 017675, 017933, 017945, 017913, 017893, 017935, 017955, 017915, 017925, 017775, 017845
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Fire
- Country of origin
- Bulgaria
Product description
The recessed luminaires are supplied with halogen lamps with a reflector, technical data: 220 V-240 V, 50-60 Hz, 50 W; a pin cap, the space between the pins is around 6 mm, and a plug with the following technical data: 24 V 250 W for luminaires No. 017725, 017943, 017853, 017903, 017905, 017875, 017933, 017945, 017935, 017955 and 017915; and25 V 100 W for luminaires No. 017953, 017793, 017705, 017675, 017913, 017893, 017925 and 017845.