EU Safety Gate · Report-2012-018

Ante · Lighting chain "LED-Háló karácsonyi ég"

The product poses a risk of electric shock and fire because:· The cross-sectional area of the wires is not sufficient and the wires can consequently overheat.· The wire ends soldered to the rectifying unit terminals and the LEDs are not adequately protected against pulling and twisting. · The accessible wires have only basic insulation and if they come into contact with the sharp edges of the rectifying unit live wires can become accessible. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Published
04 May 2012
Notifying authority
Hungary
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Open the original alert before further use and follow the measures stated there.

Official source alert
Safety Gate reference
0682/12
Model
DCH (on packaging)
Batch
5 999048 633712
Check-digit validated barcodes
5999048633712
Category
Lighting chains
Risk type
Electric shock, Fire
Country of origin
People's Republic of China

Lighting chain with 40 serial connected, non-replaceable LED lamps.