RecallLookupBack to the product checker
Serious riskSerious risk

EU Safety Gate · Report-2012-020

A.I.&E · Lighting chain "100 LED VILÁGIT" (100 LED light)

The product poses a risk of electric shock because: - the wire ends soldered to terminals of the flashing switch and control unit and the LEDs are not adequately protected against pulling and twisting:- the accessible wires have only basic insulation and they come into contact with sharp edges of the flashing control unit. In case of damage, the live metal parts become accessible;- the decorative lighting chain is recommended for outdoor use although it is not protected against moisture. The product poses a risk of fire because the cross-section area of the wires is less than the minimum requirement, thus, they can overheat. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

Published
18 May 2012
Notifying authority
Hungary
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Open the original alert before further use and follow the measures stated there.

Official source alert
Safety Gate reference
0737/12
Model
XN-714
Batch
354203
Category
Lighting chains
Risk type
Electric shock, Fire
Country of origin
Not published

The lighting chain includes serial-parallel connected, non-replaceable 100 LED lamps. The product can be operated with a flashing control unit. Main parts of the lighting chain: two-pin plug ("2.5A 250V"), flashing control unit, single-insulated mains cable with single-core, without marking. Technic