Eco Light Nordic · LED lamp tube

The product poses a risk of electric shock because:- during mounting the free-end connector of the LED tube might be live;- the clearance and the creepage distances are not sufficient;- the insulation resistance is not sufficient;- internal basic insulated conductors are in contact with the metal body of the lamp;- the mechanical strength of the silicone insulation of the conductors is weak and can be easily damaged. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60598.

Published
25 June 2010
Notifying authority
Sweden
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Withdrawal from the market and recall from consumers ordered by the authorities.. Date of entry into force: Unknown

Official source alert
Safety Gate reference
0966/10
Model
1100-LED-TUBE-SMD-T10-18W-1200mm
Category
Lighting equipment
Risk type
Electric shock
Country of origin
Not published

LED lamp tube intended to replace a traditional fluorescent tube in the original (existing) luminaire.