RecallLookupBack to the product checker
Serious riskSerious risk

EU Safety Gate · Report-2020-13

Lexxa Durable X · Digital multimeter / Digitaalinen Yleismittari

The insulation of the test leads melts during use leaving live parts accessible. The product lacks the compulsory over-current protection and its clearance and creepage distances between opposite polarities are insufficient. The user could touch accessible live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 61010-1, EN 61010-2-033 and EN 61010-031.

Published
27 March 2020
Notifying authority
Finland
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Type of economic operator to whom the measure(s) were ordered: Distributor. Category of measure(s): Recall of the product from end users. Date of entry into force: 31/10/2019

Official source alert
Safety Gate reference
A12/00457/20
Model
MAS830L (tuote 430 310)
Check-digit validated barcodes
6420617643102
Category
Electrical appliances and equipment
Risk type
Electric shock
Country of origin
People's Republic of China

Digital multimeter of category III for a maximum of 600 V and/or 10 A.