RecallLookupBack to the product checker
Serious riskSerious risk

EU Safety Gate · Report-2021-45

TEX-TECH · FFP2 respiratory mask high filtration efficiency

The particle/filter retention of the material is insufficient (measured values: as low as 83%). Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect. Furthermore, the physical resistance of the filtering material is too high (measured values of exhalation resistance: up to 3,8 mbar). Consequently, it may prevent a sufficient quantity of air to be exhaled, causing difficulties to breathe. The product does not comply with the Personal Protective Equipment (PPE) Regulation and with the relevant European standard EN 149.

Published
12 November 2021
Notifying authority
Germany
Catalog checked
30 July 2026
What should you do?

Check the authority measure and original alert.

Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Ban on the marketing of the product and any accompanying measures. Date of entry into force: Unknown. Type of economic operator taking notified measure(s): Retailer. Category of measure(s): Recall of the product from end users. Date of entry into force: Unknown

Official source alert
Safety Gate reference
A12/01531/21
Model
FFP2 Premium
Batch
01102020/T
Check-digit validated barcodes
8594176575094
Category
Protective equipment
Risk type
Health risk / other
Country of origin
Czechia

White masks with ‘TEX-TECH FFP2 Premium’ labelling. The number 1040 appears next to the CE mark on the masks.