EU Safety Gate · Report-2020-52
Welooo · KN95 Filtering half mask
The particle/filter retention of the material is insufficient (measured value 44,1%). Consequently, an excessive amount of particles or microorganisms might pass through the mask, increasing the risk of infection if not combined with additional protective measures. The product does not comply with the Personal Protective Equipment Regulation and with the relevant European standard EN 149.
- Published
- 25 December 2020
- Notifying authority
- Germany
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Importer. Category of measure(s): Destruction of the product. Date of entry into force: 07/12/2020 · Type of economic operator taking notified measure(s): Retailer. Category of measure(s): Recall of the product from end users. Date of entry into force: 25/11/2020
Official source alertProduct identification
- Safety Gate reference
- A12/01886/20
- Model
- KN95 / FFP2
- Batch
- 20200417
- Check-digit validated barcodes
- 6973109940017
Classification
- Category
- Protective equipment
- Risk type
- Health risk / other
- Country of origin
- People's Republic of China
Product description
Single use particle half-face filter mask for protection against particles and aerosols, labelled KN95 and FFP2. The product is embossed with "KN95" on the side.