EU Safety Gate · Report-2015-013
LA FOIR'FOUILLE · Guirlande 50 L.E.D. 5m
The electrical insulation is not adequate. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 61347.
- Published
- 03 April 2015
- Notifying authority
- France
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Other. Category of measure(s): Withdrawal of the product from the market. Date of entry into force: 23/02/2015 · Type of economic operator taking notified measure(s): Other. Category of measure(s): Recall of the product from end users. Date of entry into force: 23/02/2015 · Type of economic operator taking notified measure(s): Other. Category of measure(s): Destruction of the product. Date of entry into force: Unknown
Official source alertProduct identification
- Safety Gate reference
- A12/0434/15
- Model
- Ref.: 10000156374-(TDL-IP-0050L31DC12006CW-C)
- Batch
- Batch: 1413Barcode: 3660092837303
- Check-digit validated barcodes
- 3660092837303
Classification
- Category
- Lighting chains
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
LED lighting chain, 5 metres, indoor/outdoor supplied in cardboard box.