EU Safety Gate · Report-2013-022
NORTONLINE · Unknown
The product poses a risk of electric shock because: · - The insulation between the primary and secondary windings of the transformer is not equivalent to reinforced insulation. - The clearance for reinforced insulation between the primary and secondary circuit and the creepage distance on the PCB are too short.- Input power conductors are not properly positioned or fixed on the PCB. Therefore, reliance is placed upon the soldering alone to maintain the conductors in position.-The pins of the mains plug can break. The product does not comply with the Low Voltage Directive (LVD) and the relevant European standard EN 60950.
- Published
- 07 June 2013
- Notifying authority
- Cyprus
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator to whom the measure(s) were ordered: Other. Category of measure(s): Withdrawal of the product from the market. Date of entry into force: 19/12/2012
Official source alertProduct identification
- Safety Gate reference
- A12/0634/13
- Model
- TC98A
- Batch
- 02030201
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
2 pin mobile phone travel charger for models K300, K500, K700, V800, T290, J300. The product is packaged in a blister pack showing the brand, the model and the following specifications of the charger: AC 100-240V, 47-63Hz, 200mA, Output Voltage: DC 4,5-9,5V 800mA.