Serious riskSerious risk
EU Safety Gate · Report-2025-32
Ceiling lamp
The lamp has no earth connection and the wires are protected with basic insulation only and are in contact with the metal parts. In case of insulation damage the user could touch accessible live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 60598-1.
- Published
- 08 August 2025
- Notifying authority
- Luxembourg
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator to whom the measure(s) were ordered: Importer. Category of measure(s): Withdrawal of the product from the market. Date of entry into force: 16/07/2025
Official source alertProduct identification
- Safety Gate reference
- SR/02869/25
- Model
- X6-241-L120cm Black Frame
Classification
- Category
- Lighting equipment
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
Metal ceiling lamp for domestic use. Product sold online, in particular via AliExpress.