EU Safety Gate · Report-2025-44
TUCSON · Water circulating pump
The mains electrical coupling to the pump can be connected in reverse without applying any undue force, contacting the live conductor with the earth terminal on the inlet. The user could therefore touch live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN60335-1, EN60335-2-7, EN60335-2-51 and EN60320-1.
- Published
- 31 October 2025
- Notifying authority
- Ireland
- Catalog checked
- 30 July 2026
Check the authority measure and original alert.
Type of economic operator taking notified measure(s): Manufacturer. Category of measure(s): Withdrawal of the product from the market. Date of entry into force: 10/04/2025 · Type of economic operator taking notified measure(s): Manufacturer. Category of measure(s): Recall of the product from end users. Date of entry into force: 06/10/2025
Official source alertProduct identification
- Safety Gate reference
- SR/03817/25
- Check-digit validated barcodes
- 5391524561050
Classification
- Category
- Electrical appliances and equipment
- Risk type
- Electric shock
- Country of origin
- People's Republic of China
Product description
Electric motor-powered water circulating pump with 5 metre, 6 metre, and 8 metre variants. The pump casing is composed of various casing materials such as cast iron, stainless steel, or bronze 220~240V / 50HZ. Product sold online in several websites.