The bulb’s diffuser can easily detach, exposing live parts. The user can touch these live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 62560.
The costume may catch fire if worn close to an ignition source and the child wearing it may get burned. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-2.
The seat adjustment mechanism may damage the wiring for the occupant protection system, which could cause the side airbag to fail to deploy in a crash or deploy unintentionally, increasing the risk of injury. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The product contains small parts (rings and bracelets) that can easily detach. A small child may put them in the mouth and choke. Furthermore, if the necklace is worn around the neck, it could form a loop and become trapped, leading to strangulation. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
The product does not provide adequate earthing protection and sufficient insulation. The user could therefore receive an electric shock. Moreover, the metal surface of the product may overheat while in use. Consequently, this poses a risk of burns for the user. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60335-1 and EN 60335-2.
The fireworks may burst or release burning material outside the safety distance of 8 m, causing damage to sight. The product does not comply with the requirements of the Pyrotechnics Directive nor with the European standard EN 15947-5.
The fireworks may burst or release burning material outside the safety distance of 8 m or below a height of 3 m, causing damage to sight. The product does not comply with the requirements of the Pyrotechnics Directive nor with the European standard EN 15947-5.
The fibrous stuffing material of the toy is easily accessible due to the weakness of the seams. A small child may put the filling material in the mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
The motorcycle has defective parts. Consequently, the oil consumption rate can deteriorate rapidly. Continuing to drive without noticing that the oil level has dropped could result in a reduction in oil pressure, which could lead to seizure of the connecting rod bearing, breakage of the connecting rod, or locking of the rear wheel. These defects could cause an accident. Furthermore, oil spilling onto a hot silencer could cause a vehicle fire. The product does not comply with the Regulation on the approval and market surveillance of two- or three-wheel vehicles and quadricycles.
The protection of the protective conductor is insufficient, which can lead to protective earth interruption. Live parts are therefore accessible to the user, who can receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive.
The product has small parts that can easily detach (key ring). A small child could put it in the mouth and choke. Moreover, the fibrous stuffing material of the toy is easily accessible. A small child could put it in the mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
The product lacks the required safety statements and instructions for use. This could lead to inappropriate use of the appliance and the user receiving an electric shock. Moreover, the product has inadequate rated voltage and rated input power which can lead it to overload, and its basic insulation can be damaged and cause high temperature rises and non-reliable earth connection. This can lead to the user receiving an electric shock or touching the overheated accessible surfaces and suffering burns. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60335-1 and EN 60335-2.
The device is not resistant to high temperatures. Consequently, its casing may deform leaving live parts accessible. The user could touch these live parts, which may lead to an electric shock. The product does not comply with the requirements of the Low Voltage Directive.
The product has small parts (the projectiles' suction cups) which may easily detach. A small child may put them in the mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The product contains an excessive volume of nicotine-containing liquid (30 ml) and an excessive concentration of nicotine (50 mg/ml). This could lead to the accidental consumption of a high dose of nicotine. Nicotine is acutely toxic and can endanger the user’s safety, notably if the product comes into contact with the skin or is ingested. The product does not comply with the requirements of the Tobacco Products Directive.
The product has long drawstrings with free ends at the level of the neck. These drawstrings can become trapped during various activities of a child, leading to strangulation. The product does not comply with the General Product Safety Regulation nor with the European standard EN 14682.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The creepage and clearance distances of the adaptor are insufficient. Additionally, the live and neutral pins are too short and close to the periphery of the plug. This could lead to the plug failing to make a secure connection with the socket, overheating and/or exploding, causing a fire. the product does not comply with the requirements of the Low Voltage Directive.
The brake pedal assembly could collapse when braking. This may lead to an accident. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The coat contains perfluorocarboxylic acid related compounds (PFCAs) (measured value: 4 940 μg/kg). These substances bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Moreover, the product has an excessive quantity of perfluorooctanoic-acid-related compounds (PFOAs) (measured value: 4.3 mg/kg). PFOAs are carcinogenic and pose a risk to the environment. The product does not meet the requirements of the REACH Regulation nor of the Persistent Organic Pollutants (POP) Regulation
The protection of the protective conductor is insufficient, which can lead to protective earth interruption. Live parts are therefore accessible to the user, who can receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive.
The toy contains an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (up to 3.8% by weight). This phthalate may harm the health by causing possible damage to the reproductive system. The product does not comply with the REACH Regulation.
The solders in the product have an excessive concentration of lead and cadmium (measured values up to 67% and 0.56% by weight, respectively). Additionally, the plastic material of the product has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP), diisobutyl phthalate (DIBP) and dibutyl phthalate (DBP) (measured values up to 16%, 1.5% and 0.14% by weight, respectively). Lead poses a risk to the environment, and cadmium bio-accumulates and poses a risk to the environment. Phthalates may harm the health by causing possible damage to the reproductive system and to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive).
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert- butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The plastic material of the product contains an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 36% by weight). This phthalate may harm the health of users, possibly causing damage to the reproductive system. The product does not comply with the REACH Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The plastic material of the product contains an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 38% by weight). This phthalate may harm the health of users, possibly causing damage to the reproductive system. The products do not comply with the REACH Regulation.
According to the list of ingredients, the product contains 2-(4-tert- butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The product contains small parts (webbing hook and hose connection) that can easily detach. A small child may put them in the mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
The solders in the flashlight have an excessive concentration of lead (measured value up to 84% by weight). In addition, the plastic material in the survival tool case has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 13.7% by weight). Lead poses a risk to the environment. DEHP poses a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 64% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 68.4% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The rivets connecting the tool's central support and the metallic chains can easily break. The teeth might consequently detach during use and hit the or user or bystanders causing injuries. The product does not comply with the requirements of the Machinery Directive nor with the Commission Decision 2012/32/EU prohibiting the placing on the market of flail-type cutting attachments for portable hand-held brush cutters.
The product poses a risk of burns, since the cross-section of the conductors is too small. This could accumulate too much heat energy and catch fire. The product does not comply with the requirements of the Low Voltage Directive nor with the European standard EN 60598-2-20.
In similar models of kettle by the importer, excessive concentration of short chain chlorinated paraffins (SCCPs) were found. The importer cannot rule out that this product does not have an excessive concentration of SCCPs.SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. The product does not comply with the Persistent Organic Pollutants (POP) Regulation.
The product is not supplied with appropriate safety information or instructions for use. Diesel heaters must only be used in sufficiently ventilated spaces, without which the user is exposed to potentially fatal concentrations of carbon monoxide. The product therefore presents a risk of suffocation. Moreover, improvements are required to marking, labelling and documentation. The product does not comply with the requirements of the Machinery Directive.
The product has an excessive concentration of cadmium (measured value: 87.9 % by weight). Cadmium is harmful to human health because it accumulates in the body, can damage the kidneys and bones and it may cause cancer. The product does not comply with the REACH Regulation.
According to the list of ingredients, the product contains Diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), which is prohibited in cosmetic products. TPO may harm the reproductive system, may harm the health of the unborn child and may cause allergic skin reactions. The product does not comply with the Cosmetic Products Regulation.
Solders in the product have an excessive concentration of lead (measured value: 77.2% by weight). In addition, the plastic material in the cord has excessive concentrations of bis(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DBP) and short chain chlorinated paraffins (SCCP) (measured values: 0.54%, and 0.51% and 1.7% by weight, respectively). Lead poses a risk to the environment. DEHP and DBP may harm the health by causing possible damage to the reproductive system.SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive) nor with the Persistent Organic Pollutants (POP) Regulation.
The product contains Δ9-tetrahydrocannabinol (Δ9-THC) and delta-9-tetrahydrocannabinolic acid (Δ9-THCA), which are psychoactive substances that can cause central nervous system disorders. The product does not comply with the Cosmetic Products Regulation.
The product has small parts (yellow rattle cover) that can easily detach. A small child may put them in their mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
According to the list of ingredients, the product contains Diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), which is prohibited in cosmetic products. TPO may harm the reproductive system, may harm the health of the unborn child and may cause allergic skin reactions. The product does not comply with the Cosmetic Products Regulation.
The plastic material of the product contains an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 47% by weight). This phthalate may harm the health of users, possibly causing damage to the reproductive system. The product does not comply with the requirements of the Commission Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive).
According to the list of ingredients, the product contains Diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide (TPO), which is prohibited in cosmetic products. TPO may harm the reproductive system, may harm the health of the unborn child and may cause allergic skin reactions. The product does not comply with the Cosmetic Products Regulation.
The toy has small parts (eyes, nose and suction cup) that can easily detach. A small child may put them in the mouth and choke. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The high-voltage battery’s cell modules could overheat during charging. This may lead to fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The plastic material of the product contains an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 12,% by weight). This phthalate may harm the health of users, possibly causing damage to the reproductive system. The product does not comply with the REACH Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl)propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
According to the list of ingredients, the product contains 2-(4-tert-butylbenzyl) propionaldehyde (BMHCA), which is prohibited in cosmetic products. BMHCA may harm the reproductive system, may harm the health of the unborn child and may cause skin sensitisation. The product does not comply with the Cosmetic Products Regulation.
The toy contains a long cord made from elastic material and can be considerably stretched during use. A child could swing the toy around the head and twist it around the neck, causing strangulation. The product does not comply with the requirements of the Toy Safety Directive nor with the European standard EN 71-1.
The bicycle's fork can break during use, leading to the person on the bicycle falling and suffering injuries. The product does not comply with the requirements of the Machinery Directive nor with the European standard EN 15194.
The solders in the product have an excessive concentration of lead (measured value up to 42% by weight). Lead pose a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 37.4% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
Due to a manufacturing issue, a small mechanical component inside the battery may come loose and cause a short circuit between the cells of the traction battery, which may lead to overheating and a fire. If this happens, a red warning symbol will appear on the dashboard. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The solders in the flashlight have an excessive concentration of lead (measured value up to 76.6% by weight). In addition, the survival tool case contains excessive levels of bis(2-ethylhexyl) phthalate (DEHP) (measured value up to 9.87% by weight). Lead poses a risk to the environment. DEHP poses a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up 83.3% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 67% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 55.1% by weight). In addition, plastic material in the cables contain excessive concentrations of dibutyl phthalate (DBP) (measured value up to 3.85% by weight). The product also has an excessive concentration of short chain chlorinated paraffins (SCCPs) (measured value up to 0.8 % by weight). Lead poses a risk to the environment. DBP poses a risk to human health and the environment. SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the Persistent Organic Pollutants (POP) Regulation.
The solders in the product have an excessive concentration of lead (measured value up to 66% by weight). Lead pose a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 73% by weight). Lead pose a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 84% by weight). Lead pose a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
There is insufficient creepage and clearance distance between circuits, and it does not meet required insulation requirements. This can lead to the user receiving an electric shock from accessible live parts. The product does not comply with the requirements of the Low Voltage Directive nor with the European standards EN 60335-1 and 60335-2.
The product's adaptor has insufficient insulation. The user could touch accessible live parts and receive an electric shock. Moreover, the mains supply cord has excessive resistance and the live and earthing pins of the product are too short and close to the periphery of the plug. This may prevent the plug from making a secure connection with the socket. This could lead to poor contact, resulting in overheating and causing fire. The product does not comply with the requirements of the Low Voltage Directive.
Due to the lack of a battery management system, the battery cells could be damaged, giving rise to the risk of fire. The product does not comply with the General Product Safety Regulation nor with the European standard EN 62619.
The solders in the product have an excessive concentration of lead (measured value up to 58.3% by weight). In addition, the plastic material in the cord has an excessive concentration of bis(2-ethylhexyl) phthalate (DEHP) and dibutyl phthalate (DBP) (measured values up to 0.48% and 1.04% by weight, respectively). Lead poses a risk to the environment. DEHP and DBP poses a risk to human health and the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The solders in the product have an excessive concentration of lead (measured value up to 0.86% by weight). Lead poses a risk to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive).
The product's cover and filling may easily catch fire if exposed to an ignition source. The product does not comply with the General Product Safety Regulation.
The chair's construction does not ensure stability. The chair may tip over, leading to injuries. The product does not comply with the General Product Safety Regulation.
The product may not operate in a depth below five metres. If the user exceeds this depth, there is a risk of the cylinder failing to provide adequate oxygen supply, leading to drowning. Moreover, the product does not have the required labelling and marking. The product does not comply with the Personal Protective Equipment (PPE) Regulation.
The cross-sectional area of the power supply cable is too low. Moreover, the power supply cable is too short. The wires may overheat and cause the insulation to become damaged making live parts accessible. The user could touch live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive, nor with the European standard EN 60974-1.
The product has long drawstrings with free ends in the neck area. These drawstrings can become trapped during various activities of a child, leading to strangulation. The product does not comply with the General Product Safety Regulation nor with the European standard EN 14682.
Due to a software error in the 360° panorama camera control unit, the reverse camera may briefly ‘freeze’ during reversing. Also, when the car is started again, the camera picture may possibly not be displayed. This could increase the risk of an accident involving persons while reversing. These persons may suffer injuries. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The product can easily ignite, posing a risk of a fire if the product is exposed to an ignition source. The product does not comply with the General Product Safety Regulation.
The cross-sectional areas of the power supply and welding cables are inadequate. Moreover, the power supply cable is too short and the wires may overheat and cause the insulation to become damaged making live parts accessible. The user could touch live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive, nor with the European standards EN 60974-1 and EN 60974-11.
The product has an excessive concentration of cadmium (measured value: 4% by weight). Cadmium is harmful to human health because it accumulates in the body, can damage the kidneys and bones, and may cause cancer. The product does not comply with the REACH Regulation nor with the General Product Safety Regulation.
The product is contaminated with the bacteria Burkholderia cepacia, which may potentially cause illness in some consumers, particularly those with a weakened immune system. The product does not comply with the Cosmetic Products Regulation.
A software issue may cause both the multimedia screen and the instrument cluster to turn completely black when the vehicle is started. When this occurs, the displays do not recover. As a result, the driver cannot see essential driving information such as vehicle speed, fuel level, or warning indicators. Driving without this information increases the risk of an accident. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The fuel rail protector may have been incorrectly assembled, which could cause its mounting bracket to fracture under certain driving conditions. In the event of a frontal collision, the fuel rail could break and leak fuel into the engine compartment, increasing the risk of fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The charging port door outer panel may not be securely attached. As a result, it could detach while the vehicle is being driven. If this occurs, the detached part could fall onto the road and create a hazard for other road users, increasing the risk of an accident. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
The plastic of the product has an excessive concentration of polycyclic aromatic hydrocarbons (PAHs), ) notably Benzo (a)pyrene (BaP), Benzo (e)pyrene (BeP), Benz (a)anthracene (BaA), Chrysene (CHR), Benzo (b)fluoranthene (BbFA), Benzo (j)fluoranthene (BjFA, Benzo (k)fluoranthene (BkFA), and Dibenz(a,h)anthracene (DBAhA) (measured values: 7.2 mg/kg, 7.1 mg/kg, 35.2 mg/kg, 27.6 mg/kg, 7.5 mg/kg, 2.6 mg/kg, 3.6 mg/kg and 0.6 mg/kg by weight respectively). These PAHs may cause cancer and are also mutagenic and toxic for reproduction. The product does not comply with the REACH Regulation.
The plastic of the product has an excessive concentration of polycyclic aromatic hydrocarbons (PAHs), ) notably Benzo (a)pyrene (BaP), Benzo (e)pyrene (BeP), Benz (a)anthracene (BaA), Chrysene (CHR), Benzo (b)fluoranthene (BbFA), Benzo (j)fluoranthene (BjFA, Benzo (k)fluoranthene (BkFA), and Dibenz(a,h)anthracene (DBAhA) (measured values: 10.8 mg/kg, 8.4 mg/kg, 38.2 mg/kg, 38.4 mg/kg, 8.9 mg/kg, 2.9 mg/kg, 4.3 mg/kg and 0.9 mg/kg by weight respectively). These PAHs may cause cancer and are also mutagenic and toxic for reproduction. The product does not comply with the REACH Regulation nor with the General Product Safety Regulation.
The plug pins are too close to the plug face periphery and therefore the plug does not make a secure connection with the socket. due to this, the user could touch the pins and receive an electric shock. The product does not comply with the requirements of the Machinery Directive.
The product has long drawstrings with free ends at the level of the neck. These drawstrings can become trapped during various activities of a child, leading to strangulation. The product does not comply with the General Product Safety Regulation nor with the European standard EN 14682
The solders in the product have an excessive concentration of lead (measured value: 63.6% by weight) In addition, the product contains excessive concentrations of bis(2-ethylhexyl) phthalate (DEHP) (.value: 1.7% by weight). The plastic of the product also contains short chain chlorinated paraffins (SCCP) (measured value up to 1,7 % by weight). Lead poses a risk to the environment. DEHP poses a risk to human health and the environment. SCCPs persist in the environment, are toxic to aquatic organisms at low concentrations and bio-accumulate in wildlife and humans, posing a risk to human health and the environment. Prolonged exposure to them through the skin may cause cancer. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive) nor with the Persistent Organic Pollutants (POP) Regulation.
Due to a defect in the manufacturing, the indicator of the oil level is not functioning correctly. This could result in a reduction in oil pressure, which could lead to seizure of the connecting rod bearing, breakage of the connecting rod, or locking of the rear wheel. This could cause an accident. The oil spilling onto a hot silencer could cause a fire. The product does not comply with the Regulation on the approval and market surveillance of two- or three-wheel vehicles and quadricycles.
The transformer is poorly built and does not meet minimum creepage and clearance distances. Therefore, it may not make a secure connection with the plug socket. Due to this, the user may have access to live parts and receive an electric shock. The product does not comply with the requirements of the Low Voltage Directive.